APP - 29
APPENDICES
Table 1.14 Synchronous control output axis error (1700 to 1799) list (Continued)
Control mode
Command generation axis
Error
code
Synchronous control
Positioning
Fixed-pitch feed
Speed
Constant-speed
JOG
Position follow-up control
Speed control with fixed
position stop
Synchronous encoder
Servo input axis
Error cause
Error
processing
Corrective action
1705
• Setting value of the synchronous
parameter "[Pr.406] Main shaft
clutch reference address setting
(150n)" is outside the
setting range.
1706
• Setting value of the synchronous
parameter "[Pr.411] Main shaft
clutch smoothing method
(150n)" is outside the
setting range.
1707
• Setting value of the synchronous
parameter "[Pr.412] Main shaft
clutch smoothing time constant
(150n)" is outside the
setting range.
• Set a value within the range.
1720
• Setting value of the synchronous
parameter "[Pr.418] Auxiliary
shaft No. (150n)" is
outside the setting range.
• The same servo input axis No.
as the output axis is set in the
synchronous parameter "[Pr.418]
Auxiliary shaft No.
(150n)".
• Set a value within the range.
• Do not set the same servo input
axis number of the output axis.
1722
• The synchronous parameter
"[Pr.421] Auxiliary shaft gear:
Denominator (150n,
150n)" is set to 0 or
lower.
Synchronous
control does
not start.
• Set a value within the range of 1
to 2147483647.
1723
• Overflow (sign reversion)
occurred in input values,
because the auxiliary shaft gear
ratio is too large.
Synchronous
control is
immediately
stopped.
• Set a smaller absolute value for
the synchronous parameter
"[Pr.420] Auxiliary shaft gear :
Numerator (150n,
150n)".
• Set a larger synchronous
parameter "[Pr.421] Auxiliary
shaft gear: Denominator
(150n, 150n)".
• Decrease the input axis speed.
1724
• Setting value of the synchronous
parameter "[Pr.422] Auxiliary
shaft clutch control setting
(150n)" is outside the
setting range.
Synchronous
control does
not start.
• Set a value within the range.