245
Communication operation and setting
4.20.7 USB communication (Pr. 547, Pr. 548)
∗
Changed setting value is valid when powering on or resetting the inverter.
z
USB communication specifications
You can perform parameter setting and monitoring with the FR Configurator. Refer to the instruction manual of the FR
Configurator for details.
Inverter setup can be easily performed using the FR Configurator by connecting the inverter and personal computer
with a USB cable.
A personal computer and inverter can be easily connected with one USB cable.
Parameter
Number
Name
Initial Value
Setting Range
Description
547
∗
USB communication
station number
0
0 to 31
Inverter station number specification
548
∗
USB communication
check time interval
9999
0
USB communication is possible
Trips in the PU operation mode (E.USB)
0.1 to 999.8s
Sets the interval of communication check time.
If a no-communication state persists for longer
than the permissible time, the inverter trips
(E.USB).
9999
No communication check
Interface
Conforms to USB1.1
Transmission
Speed:
12Mbps
Wiring Length
Maximum 5m
Connector
USB mini B connector (receptacle mini B type)
Power supply
Self-power supply
REMARKS
USB cable available on the market
Parameters referred to
Pr. 551 PU mode operation command source selection
USB cable
USB connector
<
How to open the USB connector cover
>
Pull the cover in the direction of arrow.
Then turn it upward.
Name
Model
Application/Specifications
USB cable
MR-J3USBCBL3M
Cable length 3m
Connector for personal computer
A connector
Connector for amplifier
mini-B connector (5 pin)