87
Adjustment of the output torque (current) of the motor
<Selection method of Advanced magnetic flux vector control>
Perform secure wiring.
Set the motor.
(Pr. 71)
Motor
Pr. 71
Remarks
Mitsubishi standard
motor
Mitsubishi high
efficiency motor
SF-JR
0 (initial value)
SF-HR
40
Others
3
Offline auto tuning is necessary.
Mitsubishi constant-
torque motor
SF-JRCA 4P
1
SF-HRCA
50
Others (SF-JRC, etc.)
13
Offline auto tuning is necessary.
Other manufacturer's
standard motor
—
3
Offline auto tuning is necessary.
Other manufacturer's
constant-torque
motor
—
13
Offline auto tuning is necessary.
∗1
, for other settings of
Pr. 71
.
∗2
for offline auto tuning.
Set the motor capacity and the number of motor poles.
(Pr. 80, Pr. 81) (Refer to page 86)
Set motor capacity (kW) in
Pr. 80 Motor capacity
and
the number of motor poles (number of poles) in
Pr. 81 Number of motor poles
.
(V/F control is performed when the setting is "9999" (initial value).
Select the control method.
(Pr. 800) (Refer to page 86)
Set "20" (initial value) in
Pr. 800
to make Advanced magnetic flux vector control
valid.
Set the operation command.
Select the start command and speed command.
(1)Start command
1)Operation panel: Setting by pressing
of the operation panel
2)External command: Setting by forward rotation or reverse rotation
command (terminal STF or STR)
(2)Speed command
1)Operation panel: Setting by pressing
of the operation panel
2)External analog command (terminal 2 or 4):
Give a speed command using the analog signal input to terminal 2 (or
terminal 4).
3)Multi-speed command:
The external signals (RH, RM, RL) may also be used to give speed
command.
Test run
As required
Perform offline auto tuning.
(Pr. 96) (Refer to page 120)
NOTE
Uneven rotation slightly increases as compared to the V/F control. (It is not suitable for machines such as grinding
machine and wrapping machine which requires less uneven rotation at low speed.
When a surge voltage suppression filter (FR-ASF-H/FR-BMF-H) is connected between the inverter and motor, output
torque may decrease.)
Summary of Contents for FR-E710W-0.1K
Page 49: ...40 MEMO ...
Page 65: ...56 MEMO ...
Page 288: ...288 MEMO ...
Page 310: ...310 MEMO ...
Page 334: ...334 MEMO ...