![Mitsubishi Electric FR-E710W-0.1K Instruction Manual Download Page 193](http://html.mh-extra.com/html/mitsubishi-electric/fr-e710w-0-1k/fr-e710w-0-1k_instruction-manual_239797193.webp)
193
Misoperation prevention and parameter setting restriction
(3) Parameter operation during password lock/unlock
∗1
Reading/writing is unavailable when there is restriction to reading by the
Pr. 160
setting. (Reading is available in NET mode regardless of
Pr. 160
setting.)
∗2
Unavailable during the operation.
∗3
Correct password will not unlock the restriction.
∗4
Parameter clear is available only from the communication option.
Parameter operation
Unlocked
Password registered
Locked
Pr. 296
= 9999
Pr. 297
= 9999
Pr. 296
≠
9999
Pr. 297
= 9999
Pr. 296
≠
9999
Pr. 297
= 0 to 4
(Read value)
Pr. 296
= 100 to 106, 199
Pr. 297
= 5
(Read value)
Pr. 296
Read
Write
×
×
Pr. 297
Read
Write
×
Performing parameter clear
×
×
Performing parameter all clear
Performing parameter copy
×
×
: enabled,
×
: restricted
REMARKS
When
Pr. 296
= any of "4, 5, 104, 105" (password lock), the setting screen for PU JOG frequency is not displayed in the
parameter unit (FR-PU04/FR-PU07).
During password lock, parameter copy of the parameter unit (FR-PU07) cannot be performed.
Parameters referred to
Pr. 77 Parameter write selection
Pr. 160 Extended function display selection
Pr. 550 NET mode operation command source selection
Pr. 551 PU mode operation command source selection