229
Communication operation and setting
∗1
When "0.01 to 9998" is set in
Pr. 37
and "01" in instruction code HFF, the data format is 6 digits (E2).
∗2
Input terminal monitor details—MRS is OFF when using the safety stop function model.
∗3
Output terminal monitor details
∗4
Details of option input terminal monitor 1 (input terminal status of FR-A7AX E kit)—all terminals are off when an option is not fitted.
∗5
Details of option input terminal monitor 2 (input terminal status of FR-A7AX E kit)—all terminals are off when an option is not fitted.
∗6
Details of option output terminal monitor (output terminal status of FR-A7AY E kit/A7AR E kit)—all terminals are off when an option is not fitted.
[Fault data]
for details of fault description
b15
b0
—
—
—
—
—
RES
—
MRS
—
RH
RM
RL
—
—
STR
STF
b15
b0
—
—
—
—
—
—
—
—
—
—
ABC
FU
—
—
—
RUN
b15
b0
X15
X14
X13
X12
X11
X10
X9
X8
X7
X6
X5
X4
X3
X2
X1
X0
b15
b0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
DY
b15
b0
—
—
—
—
—
—
RA3
RA2
RA1
Y6
Y5
Y4
Y3
Y2
Y1
Y0
For read data H30A1
(Previous fault ...... THT)
(Latest fault...OP1)
0
1
0
1 0 0 0 0
0
0
1
0
0
0
1
1
b15
b8b7
b0
Latest fault
(HA1)
Previous fault
(H30)
Fault record display example (instruction code H74)
Data
Definition
H00
No fault
present
H10
E.OC1
H11
E.OC2
H12
E.OC3
H20
E.OV1
H21
E.OV2
H22
E.OV3
H30
E.THT
H31
E.THM
H40
E.FIN
H52
E.ILF
H60
E.OLT
H70
E.BE
H80
E.GF
H81
E.LF
H90
E.OHT
HA0
E.OPT
HA1
E.OP1
HB0
E.PE
HB1
E.PUE
HB2
E.RET
HB3
E.PE2
HC0
E.CPU
HC5
E.IOH
Data
Definition
HC7
E.AIE
HC8
E.USB
HC9
E.SAF
HD8
E.MB4
HD9
E.MB5
HDA
E.MB6
HDB
E.MB7
HF1
E.1
HF5
E.5
HF6
E.6
HF7
E.7
HFD
E.13
Data
Definition