16
Main circuit terminal specifications
2.2 Main circuit terminal specifications
2.2.1
Specification of main circuit terminal
∗1
When using single-phase power input, terminals are R/L1 and S/L2.
∗2
Terminal P1 is not available for single-phase 100V power input model.
2.2.2
Terminal arrangement of the main circuit terminal, power supply and the motor
wiring
Three-phase 200V class
Terminal
Symbol
Terminal Name
Description
R/L1,
S/L2,
T/L3
AC power input
Connect to the commercial power supply.
Keep these terminals open when using the high power factor converter (FR-HC) or
power regeneration common converter (FR-CV).
U, V, W
Inverter output
Connect a three-phase squirrel-cage motor.
P/+, PR
Brake resistor connection
Connect a brake resistor (FR-ABR, MRS type, MYS type) across terminals P/+ and
PR.
(The brake resistor can not be connected to the 0.1K or 0.2K.)
P/+, N/-
Brake unit connection
Connect the brake unit (FR-BU2), power regeneration common converter (FR-CV)
or high power factor converter (FR-HC).
P/+, P1
DC reactor connection
Remove the jumper across terminals P/+ and P1 and connect a DC reactor.
Single-phase 100V power input model is not compatible with DC reactor.
Earth (Ground)
For earthing (grounding) the inverter chassis. Must be earthed (grounded).
FR-E720-0.1K(SC) to 0.75K(SC)
FR-E720-1.5K(SC) to 3.7K(SC)
FR-E720-5.5K(SC), 7.5K(SC)
FR-E720-11K(SC), 15K(SC)
Screw size
(M3.5)
Motor
Power supply
N/-
P/+
PR
IM
R/L1 S/L2 T/L3
Jumper
Screw size (M3.5)
Screw size
(M4)
Motor
Power supply
N/-
P/+
PR
IM
R/L1 S/L2 T/L3
Jumper
Screw size (M4)
Motor
Power supply
IM
N/-
P/+
PR
R/L1 S/L2 T/L3
Jumper
Screw size (M5)
Screw size
(M5)
N/-
P/+
PR
R/L1
S/L2
T/L3
Jumper
Screw size
(M5)
Motor
Power supply
IM
Screw size(11K:M5/15K:M6)