Spline interpolation
Appendix-641
(8) Editing the spline file
■
Adding path point data
If the [Append] button in the path point data list area is clicked, new path point data is added to the end of
the list.
The default values are the values shown in
"Default value when newly added".
(A line can also be added by clicking the menu [Edit]
→
[Append].)
Fig.7-52:Adding path point data
Select random path point data and click the right mouse button. The context menu will open, so click [Insert].
New path point data will be inserted before the selected path point data.
(A line can also be added by clicking menu [Edit]
→
[Insert].)
Output signal
Head No.
Designate the head address of the output signal.
Setting range: –1 to 32767 (–1 means signal output invalid.)
-1
Bit width
Designate the bit width of the output signal.
Setting range: 1, 8, 16, 32 [bit]
1
Bit mask
Designate the mask pattern of the bit with valid signal output.
0
Setting value
Designate the data to be signal output.
0
Pulse output
Designate the pulse output.
Setting range: Check (designation enabled), No check (designation
invalid)
No check
Data item
Details
Default value when
newly added
Bit width
Setting range [hex]
1
0, 1
8
0 to FF
16
0 to FFFF
32
0 to FFFFFFFF
Bit width
Setting range [hex]
1
0, 1
8
0 to FF
16
0 to FFFF
32
0 to FFFFFFFF
[Append]