5-454
Signal parameter
5Functions set with parameters
Output signal reset
pattern
Refer to
"5.14About the
output signal reset
pattern"
Set the operation to be taken when the general-purpose output signal for the Clr command or
dedicated input (OUTRESET) is reset. Signals are output in the pattern set here even when the
power is turned ON.
Set with a 32-bit unit for each signal using the following parameters.(OFF/ON/hold=0/1/*)
Note) A bit set to "* (maintain)" is turned off when the power is turned on.
ORST0
Character
string 4
Set the signal No. 0 to 31.
00000000,000000
00,00000000,0000
0000
ORST32
:
ORST8016
Character
string 4
Set the signal No. 32 to 63.
:
Set the signal No. 8016 to 8047
Note) The output signals of 716 to 723 are used for Open or
Close of the multi-hand. And, setting of the output signals of 700
to 715 are impossible for the system reservation area.
00000000,000000
00,00000000,0000
0000
:
ORS10000
:
ORS18160
Character
string 4
Set the signal No. 10000 to 10031.
:
Set the signal No. 18160 to 18191.
00000000,000000
00,00000000,0000
0000
:
Output reset at
reset
SLRSTIO
Integer 1
Designate the function to carry out general-purpose output sig-
nal reset when the program is reset.
(Invalid/Valid=0/1)
0(Invalid)
Multi CPU quan-
tity setting
(CR7xx-Q series
only)
QMLTCPUN
Integer 1
At the multi CPU system, set the number of CPU units with
which the standard base unit is equipped.
2
Multi CPUn high-
speed communi-
cation area setting
(CR7xx-Q series
only)
QMLTCPUn
n=1 to 4
Integer 4
At the multi CPU system, set the number of points performing
transmission and receipt between each CPU unit for the high
speed communication function between multi CPU nos. 1 to 4.
It is necessary to match the parameter settings for all CPUs. An
error will occur at the sequencer CPU If the parameter settings
do not match, and therefore care should be taken to ensure that
the parameter settings for each CPU match.
First element: User free area size (k points)
Range: 1 to 14 (Max. *) * The max. value will differ based on
the number of multi CPUs as shown below.
Second element: No. of auto refresh points (points)
Range: 0 to 14335
The robot CPU does not support auto refresh, and therefore
the number of points for auto refresh should always be set to
0.
Third element: System area size (K points)
Range: 1 or 2
Fourth element: Multi CPU synchronous start-up (1: Yes, 2: No)
Robot CPUs take some time to start up and therefore the cur-
rent setting of 1 (synchronous start-up) should not be
changed.
1,0,1,1
Parameter
Parameter
name
No. of arrays
No. of characters
Details explanation
Factory setting
CPU Qty
Setting Range
2
0 to 14K points
3
0 to 13K points
4
0 to 12K points