6-550
Parameter for behavior selection at the error occurrence on dual system
5Functions set with parameters
5.27 Parameter for behavior selection at the error occurrence on dual system
When the parameter CATEGORY is set for the error on dual system shown in
, the behavior of
the [RESET] key input at the error occurrence on dual system can be selected.
Table 5-49:Target error list
The behavior of the [RESET] key input is set as shown in
Table 5-50:Action to the settings
To reflect the settings of this parameter, you must turn the controller's power on again.
[Note]
The setting shown in this section is to select the behavior in a state without any abnormalities on the related
signal lines or wiring.
With the abnormalities, the errors shown above cannot be reset regardless of the parameter setting.
Error number
Content
H0039
Door Switch Signal line is faulty.
H0046
Faulty wiring (Enabling Device).
H0051
Wiring of the external emergency stop is abnormal.
Parameter settings
Content
3 (Enable the error reset)
Error can be reset. (Default settings)
4 (Disable the error reset)
Error cannot be reset.