5-492
About the communication setting (Ethernet)
5Functions set with parameters
5.15.3 Example of setting of parameter 2-1
(When the data link function is used: When the controller is the server)
Shows the example of the setting, when the controller is server by the data link function.
Next, set the personal computer IP address to 192.168.0.2. Set this value on the Network Properties
screen.
Windows XP (lower left screen), Windows Vista (lower right screen)
The personal computer IP address is set with the Windows TCP/IP Property Network setting (property in
network computer). Because the set-up screen differs with versions of Windows, refer to the manuals
enclosed with Windows, etc., for details on setting this address.
Refer to the instruction manuals enclosed with the personal computer support software for details on setting
and using the personal computer support software.
Item
Setting value
Robot controller IP address
192.168.0.
20
Personal computer IP address
192.168.0.2
Robot controller port No.
10003
Communication line No.
Open command COM No.
COM3:
Parameter name to be
changed
Before/after change
Parameter value
NETIP
Before
192.168.0.20
After
192.168.0.20 (With the default value.)
NETPORT
Before
10000,10001,10002,10003,10004,10005,10006,10007,10008,10009
After
10000,10001,10002,10003,10004,10005,10006,10007,10008,10009
(Default value)
CPRCE13
Before
0
After
2
COMDEV
Before
RS232, , , , , , ,
After
RS232, , OPT13, , , , ,