Maintaining the Capping Station
4-9
1
1
1
4
Routine Maintenance
12
Clean the area around the wiper.
• Dip the clean stick in the maintenance liquid07, and wipe clean the wiper guide upper portions and the
portions one level below.
13
Press the
key after the cleaning.
14
Close the right maintenance cover then press the
key.
• After its initial operation, the machine returns to step1.
Procedure2
1
Press the
key in LOCAL.
2
Press the
key.
3
Press
to select [STATION MAINT.].
4
Press the
key.
• The carriage moves to the maintenance position.
Wiper guide
Wiper guide
Wiper guide upper portions and portions one level below
C l o s e a c o v e r
COMP L E T ED
[ ENT ]
CARR I AGE OUT
[ ENT ]
MAINT.
MOVE POS I T I ON
: S T A T I ON MA I NT .
MOVE POS I T I ON
: S T A T I ON MA I NT .
Carriage