Technical Information
192
G1000 / G2000 Dishwashers
V17. 5N1, M6, wash sequence with bottom spray arm sensor (mini program):
This starts with 30 sec. drainage, which begins with pulsed priming (2 sec. on
/ 2 sec. off). The water inlet valve is then activated (on models with and
without slide shutter) until 5.4 l has been taken in. At the same time the water
inlet valve is activated, the slide shutter is set to the middle spray arm
position. The circulation pump with switched auxiliary winding is then
operated. After 2 sec. the slide shutter is set to the top/bottom spray arm
position. If a spray arm fault is registered during circulation pump operation,
the pump is switched off after 60
sec., otherwise it operates for a further
120 sec.
6.6
LaPerla - G2830
6.6.1
G2830 - Program Mode
Initial
requirements
1. Close the door.
2. Switch off the machine.
Accessing
Press and hold the
C (Clear)
touchpad.
Switch on the machine.
Release the
C (Clear)
touchpad.
Immediately press and release the
C (Clear)
touchpad 5 times and at the 5th time
hold for 4 seconds.
Acknowledgement Indicator
Successful accessing of the Service Dept. programming mode is indicated by the
LEDs, which are all off and the indication
Service programming
shown in the right
display.
The display shows two parameters at the same time.
Use the cursor button to scroll the display.
Options
Refer to Tables: 6-54 through 6-56.
Note
Some of the following parameters can also be programmed via the
Settings
menu.