Technical Information
88
G1000 / G2000 Dishwashers
1
Middle Spray Arm Sensor
2 Flowmeter
Circuit
Board
3
Lower Spray Arm Senso
4
Solenoid for EGS Valve
5
Solenoid for Reactivation
Figure 5-29:
Water Intake Mixer Assembly and Related Components
5.4.11
EGS Valve Solenoid - Removal
1. Remove the left side panel (5.1.1).
2. Remove the drip pan (5.1.2).
3. Remove the connecting strip (5.3.4).
4. Disconnect the electrical connector from the solenoid.
5. Press the retaining lugs to the side
6. Remove the EGS valve upwards.
5.4.12
Reactivation Valve – Removal