Technical Information
G1000 / G2000 Dishwashers
Flashing
rhythm of
Intake/Drain
LED
Function Programming
Indication
Flashing rhythm of
SaniWash LED
Long Short
Long Short
- -
Pos. 0:
Software
version ID
check
Do not press the
Program button. The
Intake/Drain LED is off.
The Sani-Wash LED is off
or flashes. Shows the
software version ID No.,
e.g. -769
- -
ID
No.
- - F0
- 1 F1
- 2 F2
1 1
F11
1 2
F12
1 3
F13
1 4
F14
1 8
F18
1 9
F19
2 4
F24
2
- 1
Pos. 1:
Fault
memory
display and
deletion
Press the Program
button 1x.
If the fault is indicated in
the SaniWash LED,
check if additional faults
are registered. Press
the Program button and
hold it until the
Intake/Drain LED
flashes. Then press the
Program button briefly.
*1
5
F25
2 6
F26
4 -
F40
5 1
F51
5 2
F52
6 9
F69
7 -
F70
To delete the fault
memory, press the
Program button and
hold until the
Intake/Drain LED
flashes. Then press the
Program button until the
SaniWash LED goes
out.
The Intake/Drain LED
flashes 1x.
If faults are saved into
memory, these are
indicated via the flashing
rhythm of the SaniWash
LED. Refer to 6.7 Fault
code summary.
The SaniWash LED is off =
F0 (no faults).
8 8
F88
Long Short
- - U0
- 1 U1
- 2 U2
- 3 U3
- 4 U4
- 5 U5
- 6 U6
- 7 U7
- 8 U8
- 9 U9
1 0
U10
1 1
U11
1 2
U12
1 3
U13
- 2
Pos.2:
Component
test
Press the Program
button 2x.
To start the component
test, press the Program
button and hold until the
Intake/Drain LED
flashes. Then press the
Program button briefly.
Press the Program
button again to access
each of the following
components. *1
The Intake/Drain LED
flashes 2x.
The flashing rhythm of the
SaniWash LED indicates
which component is
currently accessed. For the
sequence of component
testing as well as
backgraound information
and access procedures,
refer to 6.2.2.3 Component
test.
1 4
U14
Table 6-15:
Service Mode (G2170) (Continued on Table 6-16)
125