Technical Information
198
G1000 / G2000 Dishwashers
Function Programming
Display
ID no. check
Select ID Number. To return to
the main menu, press the OK
touchpad.
The display shows version ID
no. for the selection-display
module (BAE) *1 and control-
power module (SLT) *2
Fault memory
display
Select Fault memory. To return
to the main menu, press the OK
touchpad.
The display shows saved fault
messages. If several faults
have been registered, they will
be indicated one after the other.
For a fault code summary, see
6.7, Fault code summary.
Alternatively, No fault is
displayed.
Fault memory
deletion
Select Fault memory. Select the
option Delete fault memory?
With the cursor touchpad, then
press the OK touchpad.
In addition to the fault
messages, the option Delete
fault memory? Is displayed.
Component
test
Select component. Individual
components V01 – V17 can be
selected via the cursor
touchpad. To return to the main
menu, press the C (Clear)
touchpad.
The display shows the
components and mini programs
that can be activated with wiring
diagram abbreviations. They
can be selected via the cursor
touchpad. After 2 sec. the
appropriate test program starts,
see 6.6.3, Component test.
Operating
hours check
Select Operating hours. To
return to the main menu, press
the OK touchpad.
The display shows the number
of operating hours
Operation: LED
test
Select Operation. Select the
option B01: LED test. To return
to the main menu, press the C
(Clear) button or touchpad.
All LEDs and the display light
up
Operation:
Buzzer test
Select Operation. Select the
option B02: Buzzer test. To
return to the main menu, press
the C (Clear) button or
touchpad.
The buzzer is activated
Table
6-57:
G2830 Service Mode Options
*1 Selection-display module
*2 Control-power module
Quit (without saving)
Switch off the unit.