The circulation pump with switched auxiliary winding is activated. With a
controlled circulation pump, the activation is at the maximum speed for
controlled operation. The circulation pump is activated for 30 sec., but the
auxiliary winding relay is only activated during the first 15 sec.
Warning!
The circulation pump must not run for more than 30 sec. without water.
Note
During the period when the auxiliary winding relay is activated, a higher
circulation pump current of approx. 0.9 A flows. Afterwards the current is
approx. 0.16 A.
V07. M24, M6, slide shutter at middle spray arm setting with circulation pump:
The slide shutter is activated and set to the top/bottom spray arm setting. The
circulation pump is then operated for 30 sec. at the maximum speed for
controlled operation.
V08. M24, M6 The slide shutter at top/bottom spray arm with pump
The slide shutter and set to top/bottom spray arm setting. The circulation
pump is then activated for 30 sec. at the maximum speed for controlled
operation.
V09. M24, The slide shutter:
The slide shutter is activated for 60 sec.
V10. Y50, combination dispenser:
The combination dispenser is activated with pulsed operation for
60 sec. The pulse rhythm throughout the test period is 10 sec. on / 10
sec.
off.
V11. Y38, Y2, Y5, …, reactivation sequence (mini program):
This starts with 30 sec. drainage, which begins with pulsed priming (2 sec. on
/ 2 sec. off). The water inlet valve with EGS (electronically controlled water
softener) valve is then activated until 250 ml has been reached or 60 sec. has
elapsed. The SIT brine valve Y60 is then activated for 150 sec. The
reactivation valve is then activated for 120 sec. Following this the water inlet
valve and the drain pump, which begins with pulsed priming (2 sec. on / 2
sec. off), are operated together for 60 sec.