Technical Information
G1000 / G2000 Dishwashers
Flashing
Rhythm of
Intake/Drain
Lt.
Function Programming
Indication
Flashing Rhythm of
SaniWash LED
Long Short
Long Short Display
- 1 EUR
Press the
Program
button 38x.
The
Intake/Drain
LED flashes 3x
long and 8x briefly
intermittently.
- 2 AUS
- 3 USA
- 4 JPN
- 5
IT/SP
3 9
Pos. 39:
Country
variant
setting *1
To change the
setting, press the
Program
button
and hold it until the
Intake/Drain
LED
flashes. Then press
the
Program
button
to enter the desired
setting changes. *2
The flashing rhythm
of the
SaniWash
LED shows which
country variant is
set: 1x = Europe;
2x = Australia; 3x =
USA; 4x = Japan,
5x = Italy/Spain, 6x
= Southern Europe.
*3.
- 6
S/EUR
Table 6-14:
G2170 Programming Mode Options (continued from Table 6-13)
*1 If the electronic unit is exchanged during service work, it must be
programmed as follows: First set the country variant and model
variant,
then switch off the unit, repeat the accessing procedure and
set the machine
height.
*2 After the changes are made, hold the program button until the Intake/Drain LED
is solid.
*3 The variant Southern Europe covers the following countries: Portugal, France,
The Netherlands, Belgium and Great Britain.
Save and quit
Switch off the unit.
123