Technical Information
G1000 / G2000 Dishwashers
Figure 5-36:
Filter Combination Lock/Unlock Positions
4. Press the large surface area fine filter downwards, Fig. 5-36, Pos. 1.
5. Fit the handle (crown coarse filter) and turn it clockwise as far as possible, Fig. 5-
36, Pos. 2.
6. Carry out a visual check: The handle (crown coarse filter) should be parallel to the
door, Fig. 5-36.
7. Carry out a functional check: Remove the filter combination and refit it.
5.4.22
Filter Combination Assembly (with Locking Piece)
Note
During assembly, the dishwasher is used as a guide.
1. Place the micro fine filter in the sump. Ensure that the lug is positioned towards
the rear of the machine.
2. Turn the micro fine filter clockwise as far as possible, Fig. 5-35.
3. Place the large surface area fine filter in position.
4. Press the large surface area fine filter downwards, Fig. 5-36, Pos. 1.
5. Fit the handle (crown coarse filter) and turn it clockwise as far as possible, Fig. 5-
36, Pos 2.
6. Carry out a visual check: The handle (crown coarse filter) should be parallel to the
door, Fig. 5-36.
7. Remove the filter combination.
8. Open the filter cap.
101