Technical Information
G1000 / G2000 Dishwashers
Table 6-41:
G1470 / G2470 Programming Mode Options (Cont. from Table 6-40) (Cont. on Table 6-42)
Flashing
Rhythm of
Delay start
LED
Function Programming
Display
Flashing Rhythm of
Rinse LED
Long Short
Long Short Display
3 8
Pos. 38:
Model
variant
setting *1
Press the Gel
button 38 times.
The Gel LED
flashes 3 times
slowly and 8 times
rapidly
intermittently. Press
the program button
as appropriate to
make the desired
setting.
The display shows
P and a digit
alternately.
Individual setting
possibilities depend
on model and
whether a
circulation pump
with slide shutter
(WAW) and sensor
softener (SEH) are
fitted as follows:
Select setting P3 =
G147x, G247x
(without WAW, with
SEH).
- 3 P3
Long Short
Long Short Display
- 1 P1
- 2 P2
- 3 P3
- 4 P4
- 5 P5
3 9
Pos. 39:
Country
variant
setting (from
software
version ID
no. 818) *1
Press the Gel
button 39 times.
The Gel LED
flashes 3 times
slowly and 9 times
rapidly
intermittently. Press
the program button
as appropriate to
make the desired
setting.
The display shows
P and a digit
alternately. The
following country
versions can be
set: P1 = EUR
(Europe); P2 =
AUS (Australia); P3
= USA, P4 = JPN
(Japan), P5 = I/E
(Italy/Spain), P6 =
SER (Southern
Europe) *3
- 6 P6
Table 6-42:
G1470 / G2470 Programming Mode Options (Continued from Table 6-41)
*1 If the electronic unit is exchanged during service work, it must be
programmed as follows: First set the country variant and model
variant,
then switch off the unit, repeat the accessing procedure and
set the machine
height. Then the on-site water hardness must be set.
*2 On models with software version ID no. 769, the “Resetting standard settings”
function is at Pos.19.
*3 The SER variant includes the following countries: Portugal, France, Netherlands,
Belgium and Great Britain
.
Save and quit