Technical Information
116
G1000 / G2000 Dishwashers
U6. M6, circulation pump switched winding relay:
The circulation pump with switched auxiliary winding is activated. With
a
controlled circulation pump, the activation is at the maximum speed for
controlled operation. The circulation pump is activated for 30 sec., but the
auxiliary winding relay is only activated during the first 15 sec.
Note
During the period when the auxiliary winding relay is activated, a higher
circulation pump current of approx. 0.9 A flows. Afterwards the current is
approx. 0.16 A.
U7. Vacant
U8. Vacant
U9. Vacant
U10. Y50, combination dispenser:
The combination dispenser is activated with pulsed operation for 60 sec. The
pulse rhythm throughout the test period is 10 sec. on / 10 sec. off.
U11. Y38, Y2, Y5,…, reactivation sequence (mini-program):
This starts with 30 sec. drainage, which begins with pulsed priming (2 sec. on/2
sec. off). The water inlet valve with EGS valve is then activated until 250 ml has
been reached or 60 sec. has elapsed. The reactivation valve is then activated
for 120 sec. Following this the water inlet valve and the drain pump, which
begins with pulsed priming (2 sec. on/2 sec. off), are operated together for
60sec.
Starting with software version ID 984 the reactivation component test operates
as follows:
At the start of the mini-program the drain pump M8, water inlet valve Y2 and
EGS valve Y5 are activated at the same time. M8 pumps water for 30 sec. and
is primed with pulsed priming (2 sec. on/2 sec. off). Y2 and Y5 are switched off
when 250 ml has been reached or 60 sec. has elapsed. The reactivation valve
Y38 is then activated for 150 sec. following this, the water inlet valve and the
drain pump, which begins without pulsed priming (2 sec. on/2 sec. off), are
operated together for 60 sec.
U12. Vacant
U13. Y38, reactivation valve:
The reactivation valve is activated for 60 sec.
U14. Vacant