Technical Information
G1000 / G2000 Dishwashers
Function Programming
Display
Resetting
standard settings
Select Factory default. If all
parameters that can be
modified by the customer
(extras and settings) should be
reset to the standard settings,
press the OK touchpad.
Otherwise, press the Back
touchpad to go back one level.
The display shows Reset factory
default settings?
Wash/Final rinse
temperature
modification (from
software version
ID no. 984).
Select Temperatures then
select the desired sub-menu.
The display shows the options Main
wash and Final rinse. This
increases the main wash or final
rinse temperature with a running
time extension.
Main
wash
Make the desired selection and
confirm with the OK touchpad
The display shows the options
Normal and Increased
Final
rinse
Make the desired selection and
confirm with the OK touchpad
The display shows the options
Normal and Increased
Water quantity
normal /
increased
Select Water plus. Make the
desired selection and confirm
with the OK touchpad
The display shows the options
Normal and Increased
Sensor softener
activation /
deactivation,
water hardness
manual setting
Select Water hardness. Make
the desired selection and
confirm with the OK touchpad
Automatic = sensor softener
activated. Alternatively the on-site
water hardness can be directly
selected. Setting range: 1°d to 70°d
(°d = Degree of German hardness).
See Table 6.2.
Program running
time reduction
(from software
version ID no.
984)
Select Shorten the program.
Make the desired selection and
confirm with the OK touchpad.
The display shows the options On
and Off (standard setting). This
offers a program-dependent running
time reduction by reducing
temperatures and/or canceling
holding times.
Second interim
rinse selection
(from software
version ID no.
984)
Select 2nd interim rinse. Make
the desired selection and
confirm with the OK touchpad.
The display shows the options On
and Off (standard setting)
Machine height
setting *2
Select Appliance height. Make
the desired selection and
confirm with the OK touchpad.
The display shows the options
Normal (G 1xxx) and XXL (G2xxx)
Country variant
setting *2
Select Country version. Make
the desired selection and
confirm with the OK touchpad.
Setting options: EUR = Europe,
AUS = Australia, USA, JPN =
Japan, I/E = Italy/Spain, SER =
Southern Europe *3
Table 6-56:
G2830 Programming Mode Options (Continued from Table 6-55).
195