Technical Information
G1000 / G2000 Dishwashers
6.3.1.3
G2140 / G2150 Component Test - Information
After selecting the service mode and successfully accessing the component test
program, individual electrical components can be activated via the program button
(Start/Stop for Integrated models). During this procedure, certain components can
only be activated via special mini-programs.
Test sequence and background information:
U1. R1, Y2, M6,…, wash sequence with heating (mini-program):
This starts with 30 sec. drainage, which begins with pulsed priming (2 sec. on /
2 sec. off). The water inlet valve is then activated (on models with and without
slide shutter) until 5.4 l has been taken in. At the same time the water inlet
valve is activated, the slide shutter is set to the middle spray arm position. After
2.7 l has been registered, the EGS (electronically controlled water softener)
valve is also opened until the total desired intake quantity has been reached.
The circulation pump with switched auxiliary winding is then operated. At the
same time the slide shutter is activated with its setting alternating at 15 sec.
intervals. After an additional 60 sec., the heating relay is switched on for 300
sec. and the water is heated to 122°F. The mini-program ends with 30 sec.
drainage, which begins with pulsed priming (2 sec. on / 2 sec. off).
Note
The mini-program does not include any fault testing function.
U2. 1K1, heating relay:
The heating relay is activated for 60 sec
U3. M8, drain pump:
The drain pump is activated for 60 sec.
U4. Y2, Y5, water inlet valves with EGS (electronically controlled water softener)
valve (mini-program):
The water inlet valve is activated (on models with and without slide shutter)
until 5.4 l has been taken in. After 2.7 l has been registered, the EGS valve is
also opened until the total desired intake quantity has been reached.
U5. Y5,
EGS
valve:
Warning!
If the flow meter is defective, the EGS valve is not activated.
The EGS valve is activated for 60 sec.
137