Technical Information
140
G1000 / G2000 Dishwashers
Flashing
Rhythm of
Intake/Drain
Lt.
Flashing Rhythm of
SaniWash LED
Function Programming
Indication
Long Short
Long Short Display
- -
Pos. 0:
Software
version ID
check
Do not press the
Program button.
The Intake/Drain
LED is off.
The Sani-Wash
LED is off or
flashes. Shows the
software version ID
No., e.g. -769
- -
ID
No.
Long Short
Long Short Display
- -
P0
-
1
Pos. 1:
Reset
Press the
Program
button 1x.
To reset all
parameters to the
delivery condition,
press the
Program
button and hold
until the
Intake/Drain
LED
flashes. Then press
the
Program
button
briefly *2
The
Intake/Drain
LED flashes 1x
briefly
intermittently. With
this programming
function, all
parameters can be
reset to delivery
condition.
If the
SaniWash
LED is
off, the values do
not correspond to
the delivery
condition. If the
SaniWash
LED
flashes, all values
are as in the
delivery condition.
- 1 P1
Long Short gr/gal
- 1 1-5
Press the
Program
button 2x.
- 2 6-9
- 3
10-14
- 4
15-19
- 5
20-25
- 6
26-31
- 7
33-38
- 8
39-45
- 9
46-63
- 2
Pos. 2: Set
the water
hardness
To modify the water
hardness setting,
press the
Program
button to enter the
desired setting
changes. *2
The
Intake/Drain
LED flashes 2x
briefly
intermittently.
The current setting
can be seen from
the flashing rhythm
of the
SaniWash
LED. If the LED
flashes 4x briefly
intermittently, this
indicates a factory
setting of 15-19
gr/gal.
1 - 64-88
Table 6-23: G1180 / G2180 Programming Mode Options (Continued on Table 6-24)