Technical Information
G1000 / G2000 Dishwashers
Test routine:
Figure 6-5: F19 –
Test routine.
•
Item a: Test time for one liter
•
If the test routine is successfully completed, water intake time will be
extended
•
If the test routine is not successfully completed, a Fault code
F19
is
registered.
Figure 6-5:
F19 – Test routine.
Refer to Fig. 6-5 for following test routine:
a. As a first step, the water intake valve
Y2
is activated, to let an
additional 2 liters into the appliance. The time required for this is
calculated based on the time the water intake took for the liter
already in the unit (see fig. 6-4).
Note
The water volume taken in at this point cannot cause an overflow, even if
the flowmeter count is inaccurate.
b. Next the circulation pump M6 is activated for 2 minutes, to wet the
dishes in the cabinet and to permit any cavities in the wash load to
fill with water. Next the drain pump M8 is activated for 1 minute.
Now a base line for the actual test has been created.
c. For the test, water intake valve
Y2
is activated until the
determined number of impulses is reached, which correspond
roughly to a water volume of 1.4 liters. Subsequently the
circulation pump
M6
is activated again.
d. The current program continues without interruption. The maximum
water intake time is extended to 4 minutes. This value is shaved in
the electronic for future water intakes. If in the future the time
necessary for the water intake of 1 liter should deviate from this
value (15% less or 15% more) a new test routine has to be
started.
213