Technical Information
182
G1000 / G2000 Dishwashers
Starting with software version ID 984 the reactivation component test operates
as follows:
At the start of the mini-program the drain pump M8, water inlet valve Y2 and
EGS valve Y5 are activated at the same time. M8 pumps water for 30 sec. and
is primed with pulsed priming (2 sec. on/2 sec. off). Y2 and Y5 are switched off
when 250 ml has been reached or 60 sec. has elapsed. The reactivation valve
Y38 is then activated for 150 sec. following this, the water inlet valve and the
drain pump, which begins without pulsed priming (2 sec. on/2 sec. off), are
operated together for 60 sec.
Warning!
If the reactivation mini program has been started, it must not be cancelled
prematurely. If it is interrupted, there is a risk that brine will overflow out
of the SIT, salt container in door, into the machine cabinet.
V12. Y60, Brine valve (salt container in door (SIT) valve):
The brine valve is activated for 60 sec.
V13. Y38, reactivation valve:
The reactivation valve is activated for 60 sec.
V14. M2, fan:
The fan is activated for 60 sec.
V15. B3/9, M6, circulation pump with Speed sensor
The circulation pump with switched auxiliary winding is activated for 30 sec. at
maximum speed. If the desired speed has not been reached within 7 sec., the
circulation pump remains station
V16. 4N1, M6, wash sequence with middle spray arm sensor (miniprogram):
This starts with 30 sec. drainage, which begins with pulsed priming (2 sec. on /
2 sec. off). The water inlet valve is then activated (on models with and without
slide shutter) until 5.4 l has been taken in. Concurrently with water inlet valve
activation, the slide shutter is set to the middle spray arm position. The
circulation pump with switched auxiliary winding is then operated. If a spray
arm fault is registered during circulation pump operation, the pump is switched
off after 60 sec., otherwise if operates for an additional 120 sec.