Technical Information
G1000 / G2000 Dishwashers
Function Programming
Display
Pos. 0:
Software
version ID
check
Do not press the
Gel
button. The
Gel
LED is off.
The display shows the software
version ID No., e.g. -769
Press the Gel button once. The
Gel
es once rapidly
intermittently. Press the
program
button. Press it again to display fault
codes that may have been saved.
The display shows
F
and a fault code
number alternately, see 6.7, Fault
code summary. If the fault memory is
empty,
F
and
0
are displayed
alternately.
LED flash
Pos. 1: Fault
memory display
and deletion
To delete the fault memory, press
the
program
button again and hold
it until
F
and
0
are shown alternately
The display shows
F
and
0
alternately.
Pos.2:
Component
test
Press the
Gel
button 2 times. The
Gel
LED flashes 2 times rapidly
intermittently. Press the
program
button. Press it again to activate the
next component.
The display shows which component
is being tested: For example if the
drain pump M8 is being tested,
U
and
3
are shown alternately. For the test
sequence and background information
about individual components and their
activation, see 6.4.2.3, Component
test.
Pos 3: Vacant When the decimal point in the
display has switched off after
approx. 6 sec., press the
Gel
button
3 times. The
Gel
LED flashes 3
times rapidly intermittently. Press
the
program
button.
The display shows = 0
Pos 4:
Operating
hours check
Press the
Gel
button 4 times. The
Gel
LED flashes 4 times rapidly
intermittently.
The display shows the number of
operating hours as follows: If the
machine has run for 74 hours,
H, 7
and
4
are displayed alternately.
Pos. 5.1: LED
test
Press the
Gel
button 5 times. The
Gel
LED flashes 5 times rapidly
intermittently. Press the
program
button.
The display shows
6.1
: All LEDs are
lit.
Pos. 5.2:
Buzzer test
Press the
Gel
button 5 times. The
Gel
LED flashes 5 times rapidly
intermittently. Press the
program
button 2 times.
This display shows
6.2
: The buzzer is
activated.
Pos. 6: Vacant Press the
Gel
button 6 times. The
Gel
LED flashes 6 times rapidly
intermittently. Press the
program
button.
The display shows
C0
.
Table
6-43:
G1470 / G2470 Service Mode Options
Quit (without saving)
Switch off the unit.
169