Technical Information
G1000 / G2000 Dishwashers
Flashing
Rhythm of
Delay Start
LED
Function Programming
Display
Flashing Rhythm of
Rinse LED
Long Short
Long Short Display
- - P0
- 5
Pos. 5:
Sensor
wash
program
modification
(from
software
version ID
No. 984)
Press the Delay
start button 5
times. The Delay
start LED
flashes 5 times
rapidly
intermittently.
Press the
Start/Stop button
as appropriate to
make the
desired setting.
The Rinse LED is off or
flashes. The display
shows P and a digit
alternately: P0 =
Normal program
sequence (standard
setting); P1 = Modified
program sequence.
This is used to adjust
the Sensor wash
program parameters so
it can be used to wash
items with stubborn
stains even if the
overall level of soiling is
otherwise low.
- 1 P1
Long Short
Long Short Display
- - P0
1 2
Pos. 12:
Resetting
standard
settings
Press the Delay
start button 12
times. The Delay
start LED
flashes once
slowly and 2
times rapidly
intermittently.
Press the
Start/Stop button
to reset all
standard
settings.
The Rinse LED is off or
flashes. This
programmable function
can be used to reset all
parameters that can be
modified by the
customer to the
standard settings. This
display shows P and a
digit alternately: P0 =
Non-standard settings
have been made; P1 =
All settings reset to
standard settings or no
modifications have
been made.
- 1 P1
Long Short
Long Short Display
- - P0
2 0
Pos. 20:
Wash
temperature
modification
(from
software
version ID
No. –984)
Press the Delay
start button 20
times. The Delay
start LED
flashes 2 times
slowly
intermittently.
Press the
Start/Stop button
as appropriate to
make the
desired setting.
The Rinse LED is off or
flashes. The display
shows P and a digit
alternately. Setting
options: P0 = Standard
setting; P1 = Wash
temperature increased.
Due to a program-
dependent running time
extension, the wash
temperature will be
increased.
- 1 P1
Table 6-32:
G2420 / G2430 Programming Mode Options (Cont. from Table 6-31) (Cont. on
Table 6-33)
153