Technical Information
G1000 / G2000 Dishwashers
Flashing rhythm
of
Intake/Drain
LED
Function Programming
Indication
Flashing rhythm of
SaniWash
LED
Long Short
Long Short
- -
Pos. 0:
Software
version
ID check
Do not press the
Program
button. The
Intake/Drain
LED is off.
The
Sani-Wash
LED is off or
flashes. Shows the software
version ID No., e.g. -769
- -
ID
No.
- - F0
- 1 F1
- 2 F2
1 1
F11
1 2
F12
1 3
F13
1 4
F14
1 8
F18
1 9
F19
Press the
Program
button 1x.
If the fault is indicated in
the
SaniWash
LED,
check if additional faults
are registered. Press the
Program
button and hold
it until the
Intake/Drain
LED flashes. Then press
the
Program
button
briefly. *1
The
Intake/Drain
LED flashes 1x.
2 4
F24
- 1
Pos. 1:
Fault
memory
display
and
deletion
If faults are saved into memory,
these are indicated via the flashing
rhythm of the
SaniWash
LED.
Refer to 6.7 Fault code summary.
2 5
F25
2 6
F26
4 -
F40
5 1
F51
5 2
F52
6 9
F69
7 -
F70
To delete the fault
memory, press the
Program
button and hold
until the
Intake/Drain
LED flashes. Then press
the
Program
button until
the
SaniWash
LED goes
out.
The
SaniWash
LED is off = F0 (no
faults).
8 8
F88
Press the
Program
button 2x.
The
Intake/Drain
LED flashes 2x.
- - U0
- 1 U1
- 2 U2
- 3 U3
- 4 U4
- 5 U5
- 6 U6
- 7 U7
- 8 U8
- 9 U9
1 0
U10
1 1
U11
1 2
U12
1 3
U13
- 2
Pos.2:
Compon
ent test
To start the component
test, press the
Program
button and hold until the
Intake/Drain
LED
flashes. Then press the
Program
button briefly.
Press the
Program
button again to access
each of the following
components. *1
The flashing rhythm of the
SaniWash
LED indicates which
component is currently accessed.
For the sequence of component
testing as well as backgraound
information and access
procedures, refer to 6.3.2.3
Component test.
1 4
U14
Table 6-29:
G1180 / G2180 Service Mode (Continued on Table 6-30)
147