MS-850 Raster Scanner User’s Manual
4-3
4–Ut
ili
ties
*Can also be set in the configuration menu or with a serial configuration command.
Command Type
Command
Name
Checksum/Part
#
<!>
Display all three Checksums of Flash memory
<!b>
Display Checksum for Boot Code
<!a>
Display Checksum for Application Code
<!r>
Display Checksum for Raster Code
<#>
Display all three Part Numbers
<#b>
Display Boot Code Part Number
<#a>
Display Application Code Part Number
<#r>
Display Raster Code Part Number
Interface
<A>
Reset (does not save for power-on)
<Ad>
Default
<An>
Restore Saved Settings
<Z>
Reset/Save (for power on)
<Zp>
Save Factory Settings
<Zd>
Save Factory Defaults
<H>
Enable Laser Scanning (Laser On)
<I>
Disable Laser Scanning (Laser Off)
<KE>*
Motor On*
<KF>
Motor Off
<L1>
Output-1 Pulse
<L2>
Output-2 Pulse
<L3>
Output-3 Pulse
Download
<d1>
Download Application Code
Status Com-
mands
<->
Input Status
<?>
Scanner Status
<?1>
Extended Scanner Status