Code Type Menu
MS-850 Raster Scanner User’s Manual
2-29
2–Menu C
o
n
fig
.
Code 128
Status
Default:
Disabled
Options:
Disabled, Enabled
Fixed Code Length
Default:
Disabled
Options:
Disabled, Enabled
Allows you to increase data integrity by ensuring that only one label length will be
accepted.
Code Length
Default:
10
Options:
1 to 64
Note:
Fixed Code Length must be enabled for Code Length to take effect.
Allows you to specify the exact number of characters that the scanner will recognize.
The scanner will ignore any code not having the specified length.
Codabar
Status
Default:
Disabled
Options: Disabled,
Enabled
Large Intercharacter Gap
Default:
Disabled
Options: Disabled,
Enabled
Allows the scanner to read labels with gaps between bar code characters exceeding
three times the narrow element width.
Check Digit
Default:
Disabled
Options:
Disabled, Modulus 16, NW 7, Both
Allows you to select the type of checksum system Codabar will use.
Check Digit Output
Default:
Disabled
Options:
Disabled, Enabled