Chapter 4
Utilities
4-10
MS-850 Raster Scanner User’s Manual
4
–
U
ti
lit
ie
s
Size
Click
Size
to enable from one to ten master labels in the master label’s data base.
Because there is a fixed data base size, as the number of master labels is increased,
the maximum characters per label will diminish. This number is posted under Max. #
of Chars. per Label: ___, just below the Size box.
The table below shows these maximums for the various master label numbers.
Associated serial commands:
See “Send Master Label Text.”
Send Master Label Text
After you’ve set the data base Size, you can enter your master label data directly
into the master label text boxes and click the Send Text button to send the label
data to the scanner.
Associated serial commands:
To create or edit master label data for master label #1, send:
<)master label data)>
or
<M1, master label data>
To create or edit master label data for a specific master label, send:
<M master label #, master label data>
Master Label
Number
Maximum
Characters
#1
2045
#2
1022
#3
681
#4
510
#5
408
#6
340
#7
291
#8
254
#9
226
#10
203