Chapter 3
Serial Configuration
3-16
MS-850 Raster Scanner User’s Manual
3–Ser
ial
Conf
ig.
AIAG
<
KZ
AIAG status, ID1, status1, ID2, status2, ID3, status3, ID4, status4,
*ID5a,ID5b,ID5c, status5, ID6, status6, ID7, status7, ID8, status8, ID9, status9, ID9,
status10, ID11, status11, ID12, status12
>
ID1 - ID12: Any ASCII 1 to 4 characters except NUL, <, >, and comma.
Note
: AIAG must be enabled to take effect.
Example: To enable AIAG and status3, send <KZ1,,1>.
Code 93
Format: <
K!
status, fixed length status, fixed length
>
Example: To enable Code 93 and fixed code length to 12, send <K!1,1,12>.
Autodiscriminate
Format: <
P
>
Enables all available symbology types. You may individually disable/enable each sym-
bology type also.
Note
:
For maximum scanning speed, enable only those bar code symbologies used in
the application.
AIAG status:
0 = Disabled
1 = Enabled
ID1 = N
ID4 = V
ID5c = G
ID8 = EB
ID11 = EL
status1:
0 = Disabled
1 = Enabled
ID2 = P
ID5a = S
ID6 = H
ID9 = ED
ID12 = EX
status 2-12:
0 = Disabled
1 = Enabled
ID3 = Q
ID5b = M
ID7 = EZ
ID10 = EC
status:
0 = Disabled
1 = Enabled
fixed code length status:
0 = Disabled
1 = Enabled
code length:
Default is
10
.
Any number from 1 to 64.