Chapter 3
Serial Configuration
3-22
MS-850 Raster Scanner User’s Manual
3–Ser
ial
Conf
ig.
Transition Counter Parameters
Transition Counter
Format: <
KH
status,minimum transitions
>
Example: To change status to enable and set minimum transitions to 24, send
<KH1,24>.
No Barcode Message
Format: <
KN
status,message
>
Example: To change the message to “NOCODE,” send <KN1,NOCODE>.
Bad Barcode Message
Format: <
K’
status,message
>
Example: To change the message to “FAULTY,” send <K’1,FAULTY>.
Scanner Setup Status Request
Format: <
KU?
>
Returns status of each command in the scanner setup group.
status:
0 = Disabled
1 = Enabled
minimum transitions:
1 to 255
Default is
14
no barcode status:
0 = Disabled
1 = Enabled
message:
Any ASCII string up to 7 characters.
Default is
NO LABEL
.
bad barcode status:
0 = Disabled
1 = Enabled
message:
Default is
BADCODE
.
Any ASCII string up to 7 characters.