Code Type Commands
MS-850 Raster Scanner User’s Manual
3-15
3–Ser
ial
Conf
ig.
Codabar
Format: <
Kq
status,start & stop match status,start & stop output status,large interchar-
acter gap,fixed code length status,code length,check digit type,check digit output
>
Example: To set Fixed Code Length to 9, send <Kq1,,,,1,9> or <Kq1,1,1,0,1,9>.
UCC/EAN-128
Format: <
Kt
,,,EAN-128 status,output format,application record separator status,appli-
cation record separator character,application brackets,application record padding
>
status:
0 = Disabled
1 = Enabled
start & stop match status:
0 = Disabled
1 = Enabled
start & stop output status:
0 = Disabled
1 = Enabled
large intercharacter gap
:
0 = Disabled
1 = Enabled
fixed code length status:
0 = Disabled
1 = Enabled
code length:
Default is
10
Any number from 1 to 64.
check digit type:
0 = Disabled
1 = Mod 16
2 = NW7
3 = Both
check digit output:
0 = Disabled
1 = Enabled
EAN-128 status:
0 = Disabled
1 = Enabled
2 = Required
output format:
0
=
Application
1 = Standard
application record
separator status:
0 = Disabled
1 = Enabled
application record separator
character:
Default is
,
Any ASCII character (except NUL)
application record
brackets:
0 = Disabled
1 = Enabled
application record
padding:
0 = Disabled
1 = Enabled