Code Type Menu
MS-850 Raster Scanner User’s Manual
2-31
2–Menu C
o
n
fig
.
Decode Output Format
Default:
Standard
Options:
Standard, Application
Allows you to choose between Standard UCC/EAN-128 and Application Record
for-
mats.
With Standard enabled, UCC/EAN-128 labels are interpreted and output in standard
UCC/EAN-128 format.
Application Record is a user-definable variation of UCC/EAN-128 that does the following:
• Separates Application Identifier fields.
• Pads variable length fields (unless disabled) with 0’s until the maximum length is
reached (except for the last field of the label).
• Passes each Application Identifier and its data field onto the application processing soft-
ware.
• Allows you to add and define separators between data fields, enclose Application Iden-
tifier’s in brackets, and disable padding.
Note
: If an illegal Application Record format is detected, then the scanner will process
it as a noread and output a noread message (if enabled).
Application Record Separator Status
Default:
Disabled
Options:
Disabled, Enabled
Note
: Application Record must be enabled under Format before this parameter can
take effect.
When enabled, a separator character is inserted between data fields.
Application Record Separator
Default:
,
(comma)
Options:
User Defined
Note
:
Application Record must be enabled under Format before this parameter can
take effect.
Allows you to define an ASCII character as a separator.
Application Record Brackets
Default:
Disabled
Options:
Disabled, Enabled
Note
: Application Record must be enabled under Format before this parameter can
take effect.
When enabled, brackets ( ) are added to enclose application identifiers.
Click Here for Serial Command(s) related to this Topic.