MS-850 Raster Scanner User’s Manual
3-3
3–Ser
ial
Conf
ig.
Function
cmd
Command Title
Format
Code Type
K!
Code 93
<
K!
status,fixed length,length>
KZ
AIAG
<
KZ
>
Kx
Background Color
<
Kx
background color
KW?
Code Type Status
Request
<
KW
?
>
Output
Kk
Noread Message
<
Kk
status,output
>
KC
Laser On/Off
<
KC
status,UNUSED1,UNUSED2
>
KS
Serial Verification
<
KS
serial command status,serial command
beep status,control/hex outpu
t>
Ku
Beeper
<
Ku
status,volume
>
Kv
Output-1
<
Kv
output on,polarity,pulse width,# before
output
>
Kw
Output-2
<
Kw
output on,polarity,pulse width,# before
output
>
K‘
Output-3
<
K‘
output on,polarity,pulse width,# before
output
>
Kl
Bar Code Output
<
Kl
status,when to output
>
KY
Partial Output
<
KY
status,start position,length
>
K/
Operational Command
Output Format
<
K/
status
>
KX?
Scanner Output Status
Request
<
KX
?
>
Setup
KE
Scans per Second
<
KE
speed
>
KD
Analog Gain Adjust.
<
KD
gain adjustment,AGC sampling
>
KP
Scanner Type
<
KP
density
>
KH
Transition Counter
<
KH
status,minimum transitions>
KN
No Barcode Output
<
KN
status,message
>
K’
Bad Barcode Output
<
K’
status,message>
KU?
Scanner Setup Status
Request
<
KU
?>
Raster Con-
trols
KR
Raster Setup
<
KR
status,top offset,bottom offset,sweep
rate,follow motor status
>
Diagnostics
K”
Warning Message Status
<K"
status1,laserhi,laserlo,novram corrupt>
K;
Laser Overcurrent
<K;
message>
K:
Laser Undercurrent
<K:
message>
K+
Over-temperature
<K+
deg,message>
K-
Under-temperature
<K-
deg,message>
K$
Lifetime Hours
<K$
hours10,message>
K%?
Present Operating Tem-
perature
<K%
deg> (read only)
K_?
Counts
<K_
powerups,resets> (read only)
K@? Time Since Last Reset
<K@
hours,minutes> (read only)
Status
K?
All Status Request
<
K?
>