Output
MS-850 Raster Scanner User’s Manual
3-19
3–Ser
ial
Conf
ig.
Beeper
Format: <
Ku
beeper status,beeper volume
>
Example: To set the beeper for On Noread and set the beeper volume to Off,
send <Ku1,0>.
Partial Output
Format: <
KY
status,start postion,length
>
Example: To enable Partial Output, set start position to 5, and set length to 6 charac-
ters, send <KY1,5,6>.
Output-1
Format: <
Kv
output on,polarity,pulse width,# before output
>
Example: To set Output-1 to Mismatch and change Pulse Width to 40 ms, and # Before
Output to 5, send <Kv2,0,4,5> or <Kv2,,4,5>.
Output-2
Format: <
Kw
output on,polarity,pulse width,# before output
>
Example: To set Output-2 to Mismatch and change Pulse Width to 40 ms, send
<Kw2,0,4> or <Kw2,,4>.
beeper status:
0 = On Good
1 = On Noread
beeper volume:
0 = Off 3 = Level 3
1 = Level 1
4 = Level 4
2 = Level 2 5 = Level 5
partial output status:
start position:
length:
0 = Disabled
1 = Enabled
Default is 1
1 to 2710
Default is 63
1 to 2710
output on (mode):
0 = Mismatch or Noread
1 = Match (or Good Read)
2 = Mismatch
3 = Noread
polarity:
0 = Negative
1 = Positive
pulse width:
Default is
5
(50 ms)
.
1 to 255
# before
output:
Default is
1
.
1 to 255
output on (mode):
0 = Mismatch or Noread
1 = Match (or Good Read)
2 = Mismatch
3 = Noread
polarity:
0 = Negative
1 = Positive
pulse width:
Default is
5
(50 ms)
.
1 to 255
# before output:
Default is
1
.
1 to 255