Chapter 2
Menu Configuration
2-22
MS-850 Raster Scanner User’s Manual
2–Menu Conf
ig
.
Multilabel
Allows you to choose the number of different labels that can be read in a single trigger
event. The following conditions apply:
1. Each label must be different to be read.
2. The maximum number of characters in any one label (other than PDF) is 64 for all
other symbols. For PDF it’s 2710.
3. The maximum number of characters in a single scan line is 102 (Code 39).
4. The maximum number of characters for all labels is 788, including preamble, sepa-
rators, and LRC.
5. All noread messages are posted at the end of the data string.
6. If more than one label is within the scan beam at the same time, label data may not
be displayed in the order of appearance.
Maximum Number of Characters per Numbers of Labels
Number of Labels
Default:
1
Options: 1
to
12
Note:
If Number of Labels is set to any number greater than one while Match Code
Type or Continuous Read 1 Output is enabled, Number of Labels will default back to
one.
Multilabel Separator
Default:
,
(comma)
Options: Any available ASCII character, except NUL.
Allows you to choose the separator character to be inserted between each label.
Number
of labels
Non-PDF Labels
Cumulative
Maximum
PDF Labels
Maximum
per label
Cumulative
Maximum
1-5
333
2710
13563
6
398
2320
13961
7
463
2030
14225
8
528
1804
14448
9
593
1622
14615
10
658
1474
14758
11
723
1350
14869
12
788
1246
14972