Output Menu
MS-850 Raster Scanner User’s Manual
2-35
2–Menu C
o
n
fig
.
Beeper Volume
Default:
Level 4
Options: Level 4, Level 5, Off, Level 1, Level 2, Level 3
Setup Outputs
Polarity
Default:
Negative
Options:
Negative, Positive
Negative is used here to designate Normally Open; Positive for Normally Closed.
Pulse Width (in 10 ms incs)
Default:
5
(.05 seconds). Corresponds to 50 ms displayed in the menu.
Options: 1 to 255 (0.05 to 2.55 seconds). Divide the number entered on the com-
mand line by 100 for time in seconds.
Allows you to set the duration of the good match/noread output signals for the output
that is enabled.
# Before Output
Default:
1
Options:
1 to 255
Allows you to determine the number of consecutive hits (matches, mismatches, or
noreads as configured by Output On) that must occur before activating Outputs 1, 2
or 3.
For example, if # Before Output is set to 3 and Output-1 is set to Noread, then Out-
put-1 will not be activated until 3 consecutive noreads have occurred.
Note
:
The hits must be consecutive and each one must match the configured Output
On condition. Any interruption in the consecutive sequence will result in a reset and
cause the scanner to start the count over.
Output On
Default:
Mismatch or Noread
Options:
Mismatch or Noread, Match, Mismatch, Noread
Allows you to set the conditions that when true will activate pins 6 and 20 (Output-1)
pins 8 and 21 (Output-2) or pins 15 and 22 (Output-3).
Note
:
If Output On is set to Mismatch or Noread, Match, or Mismatch, activation
(switching) will not occur unless Match Code Type is enabled and a master label is