Chapter 4
Utilities
4-2
MS-850 Raster Scanner User’s Manual
4
–
U
ti
lit
ie
s
Summary of Utility Serial Commands
Command Type
Command
Name
Read Rate
<Cp>
Enter Single Label Percent Rate Test
<C>
Enter Single Label Decode Rate Test
<Cm>
Enter Multilabel Percentage Rate Test
<Cs>
Enter Multilabel Decode Rate Test
<Ce>
Enter Extended Decode Rate Test for Single or Multilabel
<a1>
PDF Information
<J>
Exit Decode Rate and Percent Rate Test
Counters
<N>
Noread Counter
<O>
Noread Counter Reset
<T>
Trigger Counter
<U>
Trigger Counter Reset
<V>
Good Read Counter
<W>
Good Read Counter Reset
<X>
Mismatch Counter
<Y>
Mismatch Counter Reset
Trigger
<char>
Serial Trigger Character
Code Type
<Q>
Enable Code 39 only
<P>
Enable All Available Codes
Master Label
<E>
Enable Master Label *
<F>
Disable Master Label*
<G>
Store Next Label Scanned as Master Label # 1
<G#>
Store Next Label Scanned as Selected Master Label
<)……)> Download Single Master Label Information
<M#,……> Download Master Label for Selected Label.
<)>
Request Single Master Label Information
<M#?>
Request Master Label Information for Selected Label
<M?>
Request All Master Label Information
<))>
Delete Single Master Label Information
<M#,>
Delete Selected Master Label Information