Page 8
Overview, Technical Data, Safety Instructions
thicknessCONTROL MTS 8202.LLT / 4350127.347
with improper use. The personal protective equipment (PPE) necessary must be pro-
vided by the operating company (customer).
-
Protective equipment: All protective equipment, including the devices installed by the
operating company, must be properly installed and functional before each start-up.
Safety devices may only be removed when the system is shut down and protected
against restarting of the measuring system (e.g. padlock on the main switch).
-
Informal safety precautions: The operating instructions must always be kept at the
measuring system. In addition to the operating instructions, the generally applicable
and local regulations for accident prevention and environmental protection must also
be provided and observed. All safety instructions and hazard warnings on the measur-
ing system must be kept in legible condition and replaced as needed.
-
Safety precautions in normal operation: Before the measuring system is switched
on, it must be ensured that nobody can be endangered from the measuring system
startup. The measuring system must be checked for external damage and the safety
equipment for functionality at least once a day.
1.3.4 Maintenance and Repair
-
Maintenance and repair: Specified adjustment, maintenance, and inspection work
must be carried out at the specified intervals.
-
Structural modifications to the measuring system: No modifications, attachments to,
or conversions of the measuring system may be made without the permission of the
manufacturer. All conversion measures require the written approval of Micro-Epsilon
Messtechnik GmbH & Co. KG. Parts of the system that are not in trouble-free condition
must be replaced immediately. In addition, only original spare and wear parts must be
used. Parts obtained from third parties are not guaranteed to have the correct design
with regard to load and safety.
-
Cleaning and disposal of the measuring system: The substances and materials used
must be handled and disposed of properly, in particular when:
working on lubrication systems and equipment
cleaning with solvents
-
System noise: The continuous sound pressure level emitted by the system is less than
70 db(A).
1.4
Training of Personnel
-
Only trained and instructed personnel are permitted to work on the system.
-
The responsibilities of personnel for operating, retooling, and maintenance must be
clearly specified. Personnel undergoing training are only permitted to work on the
system under the supervision of an experienced person.
Only trained personnel are permitted to operate the controller.
The training should be acknowledged in writing.
User group
Task
Qualification
Technical staff
Initial operation, mainte-
nance, repair
Technical education
Operating personnel
Operation
Instruction, experienced/trained
1.5
Foreseeable Misuse
If the target/strip material flow has started, the calibration component holder may not be
retracted. Collision of the target/strip material with the calibration part holder.
During the reference measurement, the target/strip material flow must not be started.
Collision of the target/strip material with the calibration part holder.
1.6
Liability for Material Defects
All components of the device have been checked and tested for functionality at the facto-
ry. However, if defects occur despite our careful quality control, MICRO-EPSILON or your
dealer must be notified immediately.
CAUTION
Danger of crushing or
shearing due to un-
controlled movement
or moving parts of the
measuring system in
case of tampering of
protective equipment.
Summary of Contents for 4350127.347
Page 1: ...thicknessCONTROL MTS 8202 LLT C frame Non contact thickness measurement Operating Instructions...
Page 10: ...Page 10 Overview Technical Data Safety Instructions thicknessCONTROL MTS 8202 LLT 4350127 347...
Page 56: ...Page 56 Installation and Initial Operation thicknessCONTROL MTS 8202 LLT 4350127 347...
Page 64: ...Page 64 Maintenance Service Spare Parts Lists thicknessCONTROL MTS 8202 LLT 4350127 347...
Page 66: ...Page 66 Declaration of Incorporation thicknessCONTROL MTS 8202 LLT 4350127 347...