Page 23
Installation and Initial Operation
thicknessCONTROL MTS 8202.LLT / 4350127.347
4.5
Electrical Power Supply
The measuring system requires an AC mains voltage of 230 VAC, ±5 % / 50 Hz for prop-
er operation.
Connect the measuring system to the supply voltage.
The measuring system must be connected as follows:
Connect the cable for the 230V / 50Hz supply to -1X0:
Signal name
Terminal block -1X0
Pin
Cable
Customer
L1 230V
1
N
3
PE
5
Cable emergency stop connection to -7X1:
Signal name
Terminal block -7X1
Pin
Cable
Customer
PNOZ contact 1
-7X1: 1
PNOZ contact 1
-7X1: 2
PNOZ contact 2
-7X1: 3
PNOZ contact 2
-7X1: 4
ES feedback
-7X1: 5
ES feedback
-7X1: 6
Local ES feedback
-7X1: 7
Local ES feedback
-7X1: 8
PE
-7X1: 9
Connect Resolver cable -4W1 to +ET1-4E1:X7 and to +CFR-4M1
Connect Motor cable -4W2 to +ET1-4E1:X107 and to +CFR-4M1
Connect SUD/NORD cable -6W1 to +ET1-6X1 (EPlan +ET1:6)
Connect 24V PC Cable -9W1 to -9E1:24V and to +ET1-9X1 (EPlan +ET1:9)
Connect EtherCAT cable -9W2 to PC -9E1:LAN1 and to +ET1-11A1:X1
Connect Sensor 1.1 cable -9W3 to -9E1:LAN2 and to +CFR-9X2
Connect Sensor 1.2 cable -9W6 to -9E1:LAN3 and to +CFR-9X4
Connect Sensor 2 cable -9W9 to -9E1: LAN4 and to +CFR-9X6
Connect Dig I/O C-frame cable -21W1 to +ET1-21X1 and to +CFR-21X2 (EPlan
+CFR:21)
Connect Constellium Profinet to -9E1:LAN5
Connect Constellium VPN to -9E1:LAN6
Connect the grounding terminal of the measuring system to the potential equaliza-
tion of the electrical installation using a potential equalization conductor of at least 10
mm².
Summary of Contents for 4350127.347
Page 1: ...thicknessCONTROL MTS 8202 LLT C frame Non contact thickness measurement Operating Instructions...
Page 10: ...Page 10 Overview Technical Data Safety Instructions thicknessCONTROL MTS 8202 LLT 4350127 347...
Page 56: ...Page 56 Installation and Initial Operation thicknessCONTROL MTS 8202 LLT 4350127 347...
Page 64: ...Page 64 Maintenance Service Spare Parts Lists thicknessCONTROL MTS 8202 LLT 4350127 347...
Page 66: ...Page 66 Declaration of Incorporation thicknessCONTROL MTS 8202 LLT 4350127 347...