Page 20
Overview of Mechanical Components
thicknessCONTROL MTS 8202.LLT / 4350127.347
1
1 Transport eye
Fig. 21 Transport eyebolts on the measuring system
i
The measuring system must in principle be transported using the four transport
eyebolts and a cross-member.
Remove the four screws of the transport locking closures on the bottom of the
wooden crate. Use an Allen (hexagonal) key and an open-end wrench to do this.
1
1 Transport lock
Fig. 22 Locking screw for transportation of measuring system
Lift the measuring system by about 6 cm and remove the bottom of the transport
crate.
Position the measuring system at its final destination. Use a crane or a forklift for
this.
Put the measuring system down carefully. Avoid jerky movements when placing the
measuring system on the floor.
i
The measuring system must not be lifted on one side and then pulled. Prevent any
damage, particularly to the projecting parts (for example the monitor or keyboard)
while transporting the measuring system.
Integrate the measuring system into your industrial environment.
Summary of Contents for 4350127.347
Page 1: ...thicknessCONTROL MTS 8202 LLT C frame Non contact thickness measurement Operating Instructions...
Page 10: ...Page 10 Overview Technical Data Safety Instructions thicknessCONTROL MTS 8202 LLT 4350127 347...
Page 56: ...Page 56 Installation and Initial Operation thicknessCONTROL MTS 8202 LLT 4350127 347...
Page 64: ...Page 64 Maintenance Service Spare Parts Lists thicknessCONTROL MTS 8202 LLT 4350127 347...
Page 66: ...Page 66 Declaration of Incorporation thicknessCONTROL MTS 8202 LLT 4350127 347...