Move
Measurement Carriage, Calibration Target
The actuators of the system can be moved via the corresponding buttons in the view
System overview
if the measurement has not been started and the necessary rights
exist. You can activate resp. deactivate these buttons via the menu
Measurement
>
Manual mode
.
Fig. 35 Manual mode
Segment
Calibration target position
The calibration target is swiveled out of the measuring gap. The
calibration target is currently in parking position, apparent from
the red arrow.
The calibration target is swiveled into the measuring gap or to
check position 1 or 2.
Two other calibration targets are integrated for additional control.
Segment
Automatic axis motor
Traverses
measurement carriage with sensor technology in
horizontal parking position.
Traverses measurement carriage with sensor technology to a
random horizontal position. The button
Go
starts the run com-
mand.
Stops the manual, horizontal run of the measurement carriage
with sensor technology
Traverses measurement carriage with sensor technology in
horizontal maximum position.
Fig. 36 Buttons in manual mode
5.4.2
Emergency Stop, Area Stop
In case of a emergency stop resp. area stop situation, both the red signal lamp on the
measuring system and also the virtual red LED
Error
in the view System overview start
to blink. After elimination of the cause and resetting of the external emergency stop sig-
nal resp. the area stop, the measurement carriage traverses in its parking position.
The state emergency stop can be set externally. The area stop is also displayed in the
view
System overview
by means of a red LED. An area stop situation does not need
to be confirmed, the traversing unit traverses in its home position. The system waits for
further commands.
In the emergency stop resp. area stop situation the motor and compressed air is imme-
diately turned off. All components can be moved manually.
Summary of Contents for 4350127.347
Page 1: ...thicknessCONTROL MTS 8202 LLT C frame Non contact thickness measurement Operating Instructions...
Page 10: ...Page 10 Overview Technical Data Safety Instructions thicknessCONTROL MTS 8202 LLT 4350127 347...
Page 56: ...Page 56 Installation and Initial Operation thicknessCONTROL MTS 8202 LLT 4350127 347...
Page 64: ...Page 64 Maintenance Service Spare Parts Lists thicknessCONTROL MTS 8202 LLT 4350127 347...
Page 66: ...Page 66 Declaration of Incorporation thicknessCONTROL MTS 8202 LLT 4350127 347...