5.4.2 Continuous resistance measurement with low current
In general, this function serves as standard
-meter with a low testing current. The
measurement is performed continuously without polarity reversal. The function can also be
applied for testing continuity of inductive components.
Test circuit for continuous resistance measurement
Figure 5.14: Tip commander and 3-wire test lead applications
Continuous resistance measurement procedure
Select continuity function using the function selector keys.
Set sub-function to
CONTINUITY
using
UP / DOWN
keys.
Enable and set the
limit
(optional).
Connect
test cable to the instrument.
Compensate
test leads resistance if necessary, (see section
.
Disconnect
from mains supply and discharge the object to be tested.
Connect
test leads to the tested object (see
Press the
TEST
key to begin performing a continuous measurement.
Press the
TEST
key to stop measurement.
After the measurement is finished
store
the result by pressing the
MEM
key (optional).
Figure 5.15: Example of continuous resistance measurement
Displayed result:
R
.............. resistance