Setting up Fixtures, Test Accessories, and Lead Connections
52 Baker DX 71-030 User Guide EN V10
www.megger.com
Armature Bar-to-bar Test Fixture
For armature bar-to-bar testing, the ATF-5000 test
fixture is required. Refer to the instructions
provided with the fixture for details on using and
maintaining the fixture. The fixture’s connectors
attach to source and sense connectors of the
Baker ZTX, Baker PP85, or Baker DX15A.
During bar-to-bar testing, adjacent bars on the
commutator are tested. In turn, all adjacent bars
around the circumference of the commutator are
tested. For example, bars 1 and 2 are tested, then
bars 2 and 3 are tested, then bars 3 and 4 are
tested. The pattern continues until all
commutator bars are tested.
Figure 53. ATF-5000 armature bar-to-bar test fixture.
Armature Span Test Fixture
For armature span testing, the ATF-4000 test fixture is required.
Refer to the instructions provided with the fixture for details on
using and maintaining the fixture.
During span testing, a group or span of bars is tested. For
example, one contact is placed on bar 1 while the other is placed
on bar 5, creating a span of 5 bars. Bar 1 and 5 are contacted
first, followed by bars 2 and 6, and so on until all bar spans are
tested.
Figure 54. ATF-4000 armature span test fixture.
Summary of Contents for Baker DX
Page 1: ......
Page 2: ......
Page 10: ...Table of Contents viii Baker DX 71 030 User Guide EN V10 www megger com...
Page 28: ...Baker DX Instrument Overview 18 Baker DX 71 030 User Guide EN V10 www megger com...
Page 38: ...Baker DX User Interface Overview 28 Baker DX 71 030 User Guide EN V10 www megger com...
Page 58: ...Setting up the Baker DX Tester 48 Baker DX 71 030 User Guide EN V10 www megger com...
Page 149: ...megger com 139 RIC Templates Figure 141 RIC template 1...
Page 150: ...RIC templates 140 Baker DX 71 030 User Guide EN V10 www megger com Figure 142 RIC template 2...
Page 155: ...Index megger com 145...
Page 156: ...megger com 146...