Procedures for Testing with the DX Host
megger.com
113
4.
Check the
Status Bar
to ensure the
Active Folder
and
Active Record
fields display the
intended target destinations for your test data.
Figure 125. Armature span test start screen.
5.
Ensure the configuration icon displays the
Standalone
icon.
6.
Touch the
Surge
icon in the mode menu.
7.
Touch the
Coil mode selection
icon then the
Arm Span
icon.
8.
Select a starting point armature bar span to use as a reference. For example, bar 1 and
bar 5 and place the probes on these bars to start the process.
9.
From this point, the process is the same as testing single coils. Refer to the “Surge
testing procedure for single-coil mode” found earlier in this chapter for detailed
instructions.
NOTE: When testing armatures, apply the surge pulse until you see the EAR graph add the new bar
information. Releasing the PTT, footswitch, or fixture button too soon can result in a collapsed waveform
and errant test data being collected.
10.
When you have completed testing all bars of the armature, return the
Voltage Output
Control
knob to
Min
(full counterclockwise rotation).
Summary of Contents for Baker DX
Page 1: ......
Page 2: ......
Page 10: ...Table of Contents viii Baker DX 71 030 User Guide EN V10 www megger com...
Page 28: ...Baker DX Instrument Overview 18 Baker DX 71 030 User Guide EN V10 www megger com...
Page 38: ...Baker DX User Interface Overview 28 Baker DX 71 030 User Guide EN V10 www megger com...
Page 58: ...Setting up the Baker DX Tester 48 Baker DX 71 030 User Guide EN V10 www megger com...
Page 149: ...megger com 139 RIC Templates Figure 141 RIC template 1...
Page 150: ...RIC templates 140 Baker DX 71 030 User Guide EN V10 www megger com Figure 142 RIC template 2...
Page 155: ...Index megger com 145...
Page 156: ...megger com 146...