Procedures for Testing with the DX Host
megger.com
111
Armature Span Tests Using the DX Host
DC motor armature windings can be tested for turn insulation integrity. Armature windings are
connected to the commutator in such a manner that all the windings are connected to each
other. As a result, the bar-to-bar inductance measurements can be very low—in the micro-henry
range.
If the inductance is so low that the standard Surge test is unable to reach the required test
voltage when testing between adjacent bars, a “span” of several bars can be tested instead. The
inductance between every 5–10 bars is often high enough to allow for a conventional Surge test
using the DX’s high-voltage leads.
Selecting a Test Voltage for the Span Test
According to Paschen’s law, the minimum breakdown voltage for air is approximately 325 volts,
which would suggest that at least 325 volts per turn of the coil being tested. If, for example,
three bars are spanned with three turns per coil then the test voltage would be: 3 x 3 x 325V =
2925V
Unfortunately, such a high voltage may exceed the dielectric strength of the commutator-to-
shaft insulation or the ground wall insulation of the coil. Therefore, a test voltage that
adequately tests the coils without overstressing perfectly good insulation would be a better
choice.
Due to variations in DC motor complexity and current standards, consult the motor’s original
equipment manufacturer, or follow company guidelines to determine optimal test voltages when
conducting span testing.
NOTICE: Review all safety information provided with the equipment and presented in chapter 1 —“General
Operating Information” before setting up or operating.
Confirm that the Baker DX setup procedure has been followed. Refer to chapter 5 —“Setting up the Baker
DX Tester” as needed.
Refer to chapter 7 —“Setting up Fixtures, Test Accessories” for information needed on this topic.
Summary of Contents for Baker DX
Page 1: ......
Page 2: ......
Page 10: ...Table of Contents viii Baker DX 71 030 User Guide EN V10 www megger com...
Page 28: ...Baker DX Instrument Overview 18 Baker DX 71 030 User Guide EN V10 www megger com...
Page 38: ...Baker DX User Interface Overview 28 Baker DX 71 030 User Guide EN V10 www megger com...
Page 58: ...Setting up the Baker DX Tester 48 Baker DX 71 030 User Guide EN V10 www megger com...
Page 149: ...megger com 139 RIC Templates Figure 141 RIC template 1...
Page 150: ...RIC templates 140 Baker DX 71 030 User Guide EN V10 www megger com Figure 142 RIC template 2...
Page 155: ...Index megger com 145...
Page 156: ...megger com 146...