MTS600 Instruction Manual
23
pressure are set to the default values.
l
When ppm value entered directly, temperature and pressure values will be
cleared.
Prism constant correction value
Reflective prisms each have their prism constant(PC). Before measurement, you
must set the prism constant correction value of the prism you are using. This
instrument
’
s prism constant correction value has been set to
“
-30
”
by default.
When the prism installs like the
right, the prism constant value
should be set to 0
When the prism installs like the
right, the prism constant value
should be set to -30
①
In distance measurement mode, press [EDM] to
come in the EDM setting, the current prism constant
value is displayed.
②
Press [PC] .Input the prism constant, press [OK].
Distance measuring mode
MTS-600 provides five kind of distance measuring mode: Fine Single
measurement (Fine S),Fine Repeat measurement(Fine R),Fine Average
measurement(Fine
Ave), Rapid Repeat measurement(Rapid R),Tracking
measurement(Tracking).
Rapid Repeat measurement (approx. 0.9 seconds/time) and Tracking measurement
(approx. 0.4 seconds/time) is suitable for survey of the movement target .In order
to obtain the higher measurement precision, the Fine measuring mode should be
selected (Fine Single mode has been set by default in factory). When Fine Ave
Psm.const. -30
Atmos.crn. 0ppm
Signal
BEEP
PC
PPM
MEAS
EDM setting
Prism constant
:
-30
OK