MTS600 Instruction Manual
62
②
Press [F2] to select offset mode as
“
Angle
”
.
Procedure will prompt sighting the target point.
③
Sight the target point accurately, press [OK], the
distance and angle of the target point are calculated.
l
Press [REC] to record the results.
l
Press [CRD] to switch the screen display from
distance values to coordinates values.
l
Press [CE] to return to step 4 ,re-sight the target point.
l
Press [OK] to finish the offset measurement.
④
Press [CRD], the coordinates of target point are
displayed(assuming that the instrument station has
been constructed).
⑤
Press [SD&A], return to display the distance and
angle of the target point again.
V.ang(Z) 89
°
40
′
48
″
H.ang(R) 145
°
26
′
17
″
Collimate target pt?
MEAS OK
>S.dist 165.274m
>V.ang(Z) 90
°
15
′
33
″
>H.ang(R) 140
°
14
′
08
″
REC CRD CE OK
>Crd N 27134.124m
E 53830.532m
Z 0.571m
REC SD&A CE OK
>S.dist 165.274m
>V.ang(Z) 90
°
15
′
33
″
>H.ang(R) 140
°
14
′
08
″
REC CRD CE OK